Techno Pex Pipes for ground heating
nets |
|
|
|
The ground heating system
depends on posing hot of low temperature (40o
- 50o)
Celsius, within a net of pipes distributed upon the ground insulator all
over the place by many circulators, thereby each circulator consist of a
single pipe (without joints), this pipe passes through a union of the
backward line. |
|
The geometric study defines
the quantity of width between the pipes. since there are differences in
temperature of the heated places, then pipes must be densities in the
cold places so that the surfaces temperatures become equal, no way must
the ground get a temperature higher than (28o
- 30o)
|
|
|
|
Characteristics |
|
►A
better exploitation of the rooms areas, with full control of the
furniture due to deletion of radiators installment.
|
|
|
|
►
The ground heating system distributes temperature equally, and prevents
cold or hot air streams as of the traditional heating. |
|
|
|
►No
black blast as existed usually over the radiators as a result of
dust - atom burning.
|
|
|
|
►Ground
heating is the idea solution for heating big areas of big hights as in
mosques churches galleries , closed, swimming, pools, and the eves
problems of heating in such places is the thermal assemblage in the high
areas. |
|
|
|
►The
correct result of the ground heating system start from the correct
geometrical designation, which Techno Therm company present
FREE. |
|
|
|
►The
cost of using Technopex pipe in ground heating system is equal to that
of heating by radiators. |
|
|
|
►The
radiation of heat, from down - up ward over all the surface of the
radiation ground, makes the heating of high performance, compared with
the other fore, gives a felling of comfort because it's the closest to
an ideal distribution of heat in the human body . |
|
|
|
|
|
|
|
|
Installation |
|
►
We put the insulator board (strawboards) on the ground of the desired
heating place there to yet the wanted insulation, this insulation is
characterized of high density and pressure with 3 cm.
|
|
|
|
|
|
►
Put the reflectors sheet
before putting the pipes thus reducing the thermal loose rate and
getting higher heating as well. |
|
|
|
►
Distribute Technopex pipes upon the reflector sheet according to a
geometrical lineation that was put by experts of the company in the
studies - department. |
|
|
|
►
Connect the pipes heads to the lopper unions existed in the cabinet
which was first fixed in a way that the pipe goes out from the outlet -
union, then goes back into an inlet-union.
|
|
|
|
►
Put the pipes under pressure
10 bar. |
|
|
|
►
Pour the cement layer (
together with special plastic material supplied by the company) and
leave expansion partings around this cement body. |
|
|
|
|
|
|
|
|
|
|
|
|